Suitable for fixed protected installation in, or on, lighting or control gear for rated voltages up to 450750 v. The cable conformed with the eu directive 200295ec on the restriction of the use of certain hazardous. Pvc insulated, nonarmoured cables for voltages up to and including 450750 v, for electric power, lighting and internal wiring british standard. These cables are not intended to be laid underground. British standard electric cables pvc insulated, non armoured. Moreover, where cables to bs 7211 are to be installed in a conduit, trunking or other containment system where moisture or condensation may exist, the cables should be selected on the basis of the manufacturers particular advice in this respect. China bs standard v bv singlecore pvc insulated non sheathed wire cables, find. Tonn cable is one of the fastest growing low voltage. Cable performance in respect of conductor resistance, construction quality workmanship. Jun 14, 2019 bs6004 standard pdf purchase your copy of bs as a pdf download or hard copy directly from the official bsi shop.
Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as iso 9001 and approved by the leading approvals organisations nationally and. A wide variety of bs6004 cable options are available to you, such as conductor material, type, and application. These cables are designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers. Prysmian guide to changes of british standard numbers en. The cable is intended for use in semiflush exposed conduits and embedded. Standard number bs find similar standar by category. Abstract gives requirements for the construction, test methods and performance of cables with polyvinyl chloride pvc insulation of. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting british standard customer service. There will be changes to existing standards bs 6004 and bs 7211 which were re issued in september 2012. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting bs 7889. Conductors are class 2 stranded except where shown. Thermosetting insulated, nonarmoured cables with a voltage of 6001 000 v, for fixed installations. Magnum cable sdn bhd 781077v pvc insulated cables for electric power and lighting single core. Most building wire has a maximum voltage rating of v, although v building wire is also available.
General wiring cables single core non sheathed bs 6004. Bs6004 6491x singlecore general purpose cable for use in conduit and trunking. Bs 6004 flat pvc insulated, pvc sheathed cable with circuit. Bs 6234 specification for polyethylene insulation and sheath of electric.
Characteristics voltage rating uou 300500v temperature rating fixed. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of mechanical damage would not be an issue. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting bs en 505251. Pvc insulated, nonarmoured cables for voltages up to and including 450750v, for electric power, lighting and internal wiring.
Low voltage energy cables of rated voltages up to and including 450750 v u0u. Electric cables low voltage energy cables of rated voltages. At the end of the test the burnt portion of cable must not be 50 mm close to the higher clamp. You may experience issues viewing this site in internet explorer 9, 10 or send your message to this supplier. Bs en 50525231 is the updated replacement for bs 6004. Bs 6004 round pvc insulated, pvc sheathed cable, 300500 v, single core, in accordance with bs 6004 application the cable is designed for electricity supply, lightning, and electrical installations. Pdf on sep 1, 2015, utsho a arefin and others published analysis of conductive materials. The cable features plain annealed copper conductors, two cores laid flat and an uninsulated circuit protective conductor in pvc insulation and a grey pvc outer sheath. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of. Low voltage energy cables of rated voltages up to and including 450750 v u0u cables for general applications. These cables can be installed in conduit, in cable trunking and in cable ducting. Pdf analysis of conductive materials, wires and cables for using. The application time of the flame is according to the cable diameter 60480 seconds. These cables are designed for surface wiring where there is little risk of mechanical damage and are suitable for use in electrical installations such as power and lighting.
The electrical and dimensional properties of this product are measured by the technical and quality assurance department at the eland cables laboratory. Many standards and codes of practice for safetycritical systems set requirements for fire performance cables, including bs 5839 for fire detection and alarm systems, bs 5266 for emergency lighting and bs 8519 for life safety and fire fighting applications. Twin and earth cable is a colloquial name in the uk, australia, new zealand and other countries for a type of flat sheathed fixed mains electricity cable, containing two insulated currentcarrying conductors and an earth connector. Check of the build up and color coding of the cable. General wiring cables low voltage cables application single core insulated conductor, without sheath, for general purposes. This cable meets the requirements of the low voltage directive 201435eu and the rohs directive 201165eu. This standard includes the national type low voltage cables which were not included in the harmonised series of cables to bs en 50525. Professional connector and cable manufacturer, with good quality and competitive price. Prysmian guide to changes of british standard numbers en 50525, bs 6004 and bs 7211 1.
Tonn cable sdn bhd, incorporated in 2002 and located in kuala lumpur, malaysia. May 11, 2019 bs6004 standard pdf purchase your copy of bs as a pdf download or hard copy directly from the official bsi shop. Bs 6004 624y twin and earth pvc cable eland cables. Indoor energy cables, wires and cables 6491x bs en 50525231 main content main menu this site uses cookies so that we can provide you with the best user experience. Rohs compliance has been tested and confirmed by the cable lab as meeting the requirements of the bsi rohs trusted kitemark tm. Bs 6004 and bs 7211 now cover only selected uk cables designs and will now include arctic flexible cords. We always attach great importance to quality controlling from the very beginning to the very end. Pvc polyvinyl chloride type tm1 to bs7655 with oxygen index 30%. Pvc insulated and pvc sheathed cables for voltages up to. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting. Manufacturers and bs cable suppliers for a wide range of high quality bs cables to suit all kinds of applications. Jun 27, 2019 bs6004 standard pdf purchase your copy of bs as a pdf download or hard copy directly from the official bsi shop. In australia and new zealand this type of cable is referred to as flat tps.
Class 5 flexible plain copper conductors to bs en 60228. Bs 6004 flat pvc insulated, pvc sheathed cable with circuit protective conductor, 300500 v, single core, flat twin and 3 core, in accordance with bs 6004 application the cable is designed for electricity supply, lightning, and electrical installations. Aei cables bs 6004 pvc conduit and house wiring types. All bsi british standards available online in electronic and print formats. This website is best viewed with browser version of up to microsoft internet explorer 8 or firefox 3.
There is an overall sheath of grey pvc bs 6004, or white for low smoke. Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as iso 9001 and approved by the leading approvals organisations nationally and internationally including basec, lpcb and lloyds. British standards electrical cable telephone cable. Standard number bs enter between 20 to 4, characters. Fixed wiring cable 6181y bs 6004 cable technicalspecification 1 of 3. Liban cables will carry out these tests on all the lengths and tests certificates will be provided. Class 1 solid copper conductor according to bs en 60228 previously bs 6360 4mm. Industrial cables british standard 2491x to bs 6004new bs en 50525231 application and description. Bs6004 standard pdf purchase your copy of bs as a pdf download or hard copy directly from the official bsi shop. Bs 6004 pvc insulated, nonarmoured cables for voltages up to and including 4501750v, for electric power, lighting and internal wiring. This british standard is the uk implementation of en 505251. The cable is subjected to the action of a flame produced by a calibrated bunsen burner. The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and highrise buildings. Bare copper class 2 conductor bs en 602 eland product group.
Single core nonsheathed cables with thermoplastic pvc insulation. Cable standards bs 6004, bs eniec 6033212 application fixed installation in dry or damp areas for domestic and light industrial wiring. Jun 23, 2019 bs6004 standard pdf purchase your copy of bs as a pdf download or hard copy directly from the official bsi shop. Bs 6004 and bs 7211 were reissued in september 2012. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting british standard. Building wire applications building wire is used to carry electricity into or within buildings and structures, and can be employed for a variety of commercial and residential applications including electrical wiring systems, power. Prysmian guide to changes of british standard numbers en 50525, bs 6004 and bs 7211. Single core pvc insulated and pvc sheathed doncaster cables. British standard bs6004 specifies the requirements for low voltage lv flexible polyvinyl chloride pvc insulated and pvc oversheathed cables commonly used in final circuits in building, including electric power supply and lighting applications with a voltage. Type of cables standards area of usage flexible cords up to 500v ms 21125, bs 6500, iec 602275 portable socketoutlet, household appliances, audiovideo products housing cables up to 750v ms 21121 to ms 21126, bs 6004 fixed wiring and lighting pvc insulated 600v to 1 kv ms 2100 to ms 2111, bs 6346 low voltage electricity supply xlpe. Specification for welding cables bs 6007 electric cables single core unsheathed heatresisting cables for. Code of practice for the emergency lighting of premises.
Fixed wiring cable bs 6004 624y twin and earth pvc cable technicalspecication 1 of 3 application domestic wiring cable. Or where there is deemed little risk of mechanical damage these cables can be clipped direct, on cable tray, embedded or in free air. Rohs trusted km 634267 bs 6004 624y twin and earth pvc cable eland product group. None of these amendments require changes to prysmian manufacturing and market practice. Samples of cables 3,5 m long in quantities required by standard. Pvc insulated, nonarmoured cables for voltages up to and. Accept and continue learn more about the cookies we use and how to change your settings. Standard number bs learn more about the cookies we use and how to change your settings. Code of practice for system design, installation, commissioning and maintenance. Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to.
Singlecore general purpose cable for use in conduit and trunking. Home publication index british standards institution bs 6004. Learn more about the cookies we use and how to change your settings. Cables are tested and verified by the standards bs en 60228, bs 6004, bs eniec 605021 flame retardant according to bs eniec 6033212 isoiec 17025 laboratory tested this product is subject to the quality assurance protocols of the cable lab, an isoiec 17025 accredited cable testing laboratory. In any event, as with any other type of cable, where cables to bs 6004 or bs 7211 are to be. Pvc insulated and sheathed, single core, flat twin and flat three core cables with bare cpc to bs 6004 conductors are class 2 stranded except where shown. Customers who bought this product also bought bs this website is best viewed with browser version of up to microsoft internet explorer 8 or firefox 3. This british standard is the uk implementation of en 50525231. Solid or stranded conductor is made from annealed copper wires. Bare copper class 2 conductor bs en 602 eland cables.
636 93 1172 681 1306 1242 1171 1169 602 277 1391 554 1163 869 820 189 1345 629 855 1115 1281 1389 1109 1185 1289 356 325 820 395 1175 1356 350 39 73 312 589 55 588 767 1031