Rs-422 driver output impedance switch

Am26ls31 datasheet quad rs422a differential line driver. Analog devices offers a wide range of standard rs485. What is the difference between rs232, rs422, and rs485. Place a distant minilogger and communicate over a full duplex serial line. Using the hs 26ct32rh radiation hardened rs422linereceiver an9520rev 4. But since its dc levels i am reckoning it will be in the range of 6v and 0v. Differential parallelterminated driver output waveforms. Data input data output optical isolator isolated 5 v be sure to answer the following questions before ordering your rs422485 board from moxa. Encoder link, rs 422 driver receiver rev d3, page 641 absolute maximum ratings beyond these values damage may occur. The main difference between rs 422 and rs 485 is that while rs 422 is strictly for pointtopoint communications and the driver is always enabled, rs 485 can be used for multidrop systems and the driver has a tristate capability. The driver stages are current limited, shortcircuit proof, and overtemperature protected. The new ichf provides 6 rs422 line drivers for 3v 5. Source impedance indicating leds power anr t bms erfi t i transmit electrical receive fiber receive electrical power required multimode. So if you plan to control devices and need no feedback from them, an rs422 multidrop network will work well figure 1a.

The rs422 standard allows only oneway simplex communications between one driver, and as many as ten receiving devices. Rs 422 cannot implement a true multipoint communications network such as with eia485 since there can be only one driver on each pair of wires. A device with an rs485 or rs 422 port might include a builtin termination resistance you can connect to a bus if needed or leave disconnected. If the enable signal is off, one can consider the driver as disconnected from the transmission line. Line drivers and receivers are commonly used to exchange data between two or more points nodes on a network.

Selecting and using rs232, rs422, and rs485 serial data standards tutorial maxim. The largest difference between rs422 and rs485 centers on the types of communications allowed. The largest difference between rs 422 and rs485 centers on the types of communications allowed. This is a differential signal and requires transmission line termination. Reduces magnetic interference in signal, available in various configurations including terminal block connection. Using the hs 26ct32rh radiation hardened rs422 line receiver. Each pushpull driver stage can drive up to 65 ma maximum at 5 v and operate at up to a 10mhz output frequency with rs422 termination.

Esdprotected rs485rs422compatible transceivers feature one driver and one receiver. Rs422 will support pointtopoint, and multidrop circuits, but not multipoint. Cmos process but uses a npn bipolar output driver to provide both high output drive and power off output isolation. The connections for two devices with receive and transmit rs422 signals is shown in figure 1. There is no possibility of the line providing sufficient. Rs422 is not strictly compatible with rs232, but most rs422 drivers will act like a singleended driver if only one output line is used. Rs422 summary of key specifications parameter conditions min max units driver output voltage, open circuit 10 v driver output voltage, loaded rl 100. The rs 485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single 2wire bus. The rs 422 standard allows only oneway simplex communications between one driver, and as many as ten receiving devices. Usb to rs422rs485 serial adapters serial terminal block. However one driver can fanout to up to ten receivers. An rs232 port can supply only limited power to another device.

With the integrated encoder link function, the line drivers can be deactivated and analogdigital signals directly accessed through the line driver output pins. The rs422 signal this standard was introduced in 1975 and offers a more robust system than the older rs232 standard. Conventional sensors can be calibrated or programmed through usual rs422 outputs, due to the encoder link function, and no extra contacts, pins, control lines or signals are required. Compared with rs422, the higher input impedance and wider commonmode range of an rs485 connection enables longer line lengths. Featuring an integrated encoder link function, the line drivers can be deactivated and analogdigital signals directly accessed through the line driver output pins.

The number of output lines, the type of interface driver ic, and the state of the output lines are important considerations. The ltc2872 can be configured as four rs232 singleended transceivers or two rs485 differential transceivers, or combinations. Rs422 charachteristic impedance and its variants stack exchange. The st485 is al low power transceiver for rs485 and rs422. A male db25p connector is provided for the ttl side. Eia485 devices may be used in 422 circuits, but eia422 may not be used in 485 circuits because of the lack of an enable line. Note, however, that motors, switches, and other electrically noisy equipment can. There are many way to terminate this signal and it depends on the characteristics of the device, in this case an ni 9411 digital input. I was looking at the differential output driver of a rs422 transceiver with my scope, i had one output connect to the scope probe and the other connected to the scope probe ground. This connection is commonly used for securitysurveillance video cameras to control the pantiltzoom available from pelco or others, or to connect displays for signage indoors or outdoors, clock displays, etc. The types of driver ics used in serial ports can be divided into three general categories. I am just analysing the effect of passives on the charachteristic impedance on the addition of extra passives. The driver is capable of transmitting data across 4000 feet recommended limit of cable. Rs422 can interoperate with interfaces designed to milstd188114b, but they are not identical.

This is due to the pchannel drivers parasitic drainbody diode, which becomes forwardbiased at voltages above ground. The standard uses a voltage differential of 2v min to 5v max. The purpose of this signal is to connect the driver to its output terminals, a and b. Therefore, the output state of the receiver may be known for both idle and tristate bus conditions in. The rs422 and rs485 circuits have basically the same principle. With this low impedance bypassing, internal analog sensor signals and digital communication signals biss, spi, i. Rs422 data routers this application note considers some of the factors involved in rs 422 machine control routing. They are sent and received in differential mode, and no digital ground is required. Short circuit protection to ground is provided by an active output sense circuit. In this way, the rs422 a output can be used to drive either an rs232 input directly. An rs485 driver must have the enable control signal. Eiatia422 defines a balanced differential interface.

The rs422 specification recommends 24awg twisted pair cable with a shunt capacitance of 16 pf per foot and 100 ohm characteristic impedance. Guide to selecting and using rs232, rs422, and rs485 serial. Rs422 driver with analog bypass for encoder applications. Differential driver output no load 55v vod2 differential driver output with load rl 27. Proper termination of the bus with a pure resistance that matches the wires impedance attenuates reflections. Rs485 driver, in addition to the output states of 1 and 0. The first version of rs422 was issued in 1975, with. February 2009 rev 16 119 19 st485b st485c low power rs485rs422 transceiver features low quiescent current. We begin with examining signal degradation on the bus and key transceiver.

Meets or exceeds the requirements of ansi tiaeia422b and itu recommendation v. Rs422 driver with analog bypass for encoder applications the new ichf provides 6 rs422 line drivers for 3v 5. So if you plan to control devices and need no feedback from them, an rs 422 multidrop network will work well figure 1a. The rs485rs422 modes feature one driver and one receiver. Rs 422 will support pointtopoint, and multidrop circuits, but not multipoint.

Driver output shortcircuit current per output to common 150 ma driver output rise time rl 100. Rs485rs422 circuit implementation guide analog devices. Dlsc flsc rs422 connection to rs485 page 47 laser distance sensors illustration 1. Rs422 cannot implement a true multipoint communications network such as with eia485 since there can be only one driver on each pair of wires. Rs422, rs485 differential line driver texas instruments. A practical guide to using rs422 and rs485 serial interfaces v. I am purchasing an incremental encoder that has an rs 422 line driver ouput. The new ichaus ichf provides 6 rs422 line drivers for 3 v 5.

These monolithic quadruple differential line drivers with 3state outputs are designed to meet the requirements of ansi standards eiatia422b and rs485 and itu recommendation v. Standard rs422 drivers are guaranteed to source and sink a minimum 20 ma across a 100. For differential rs422 line driver operation, six differential complementary drivers are implemented. I am purchasing an incremental encoder that has an rs422 line driver ouput. Singleended, ttlcompatible input signals are transmitted as differential, 5v rs422 output signals at a rate up to 10mhz. The rs485rs 422 modes feature one driver and one receiver. Very high speed low power rs 485rs 422 transceiver features low supply current. Encoder link, rs422 driverreceiver rev c1, page 236 description ichf is a robust line driver for industrial 5v control applications featuring six differential output channels. The 422ttl unit converts rs 422 signals to ttl signals. Smith serial communication products is your rs485 rs232 and rs422 authority for converters, repeaters, microprocessors, fiber optics, ethernet serial port server, ethernet serial products, mei, nodes and networks, usb, serial and digital io solutions, serial and analog io solutions including rs485, rs232, rs422, rs 485, rs 232, rs 422, telemetry, process control, translators, extenders. Eia485 devices may be used in 422 circuits, but eia 422 may not be used in 485 circuits because of the lack of an enable line. The usbrs422pcb is a usb to rs422 level serial uart converter pcb incorporating ftdis ft232rq.

Selecting and using rs232, rs422, and rs485 serial data. Rs422 line driver description the hs26ct31rh is a radiation hardened rs422 line. Design considerations for highspeed rs485 data links. Transceivers, optocouplers, and a transformer provide a complete interface in a standard dip package.

The driver or generator is labeled d, the receiver is labeled r, and the termination impedance is zt. So, supposing, i add some resistors as shown, what will the impact be. The terminations are placed at the driver and receiver farthest from each other. Application note an06 high speed, high reliability twisted. Noninverting receiver input and noninverting driver output. Since both rs 422 and rs 485 are data transmission systems that use balanced differential signals, it is appropriate to discuss both systems in the same publication.

The termination resistance must be equal to the cable impedance recommended. Feb 14, 2014 the new ichaus ichf provides 6 rs422 line drivers for 3 v 5. Using the hs 26ct32rh radiation hardened rs 422 line receiver. Because renesas transceivers offer precise switching characteristics due to very low. The receiver input has a failsafe feature that guarantees a known output rolow for the.

Transceivers, optocouplers, and a transformer provide a complete. Rs422, also known as tiaeia422, is a technical standard originated by the electronic industries alliance that specifies electrical characteristics of a digital signaling circuit. Multidrop links are used for legacy rs422 applications and clock distribution. The driver provides a low internal impedance that terminates the line at that end. The 422ttl unit converts rs422 signals to ttl signals. Full operation requires only four external charge pump capacitors. Vod change in magnitude of driver differential output voltage for complementary output states rl 27.

Rs422 line driver to ni digital input termination ni. The rs485rs422 io pins are protected against 15kv electrostatic discharge esd shocks, without latchup. Sep 08, 2015 the largest difference between rs 422 and rs 485 centers on the types of communications allowed. To illustrate their basic differences, a condensed description of each standard is presented in the following subsections. Documents any isolated rs 422 driver with no bit errors during eft test. Depending on the device receiver type, up to 32 12k impedance nodes or 11 rs 422 receivers can be connected without a repeater. Rs232rs485 dual multiprotocol transceiver with integrated termination the ltc2872 is a robust pinconfigurable transceiver that supports rs232, rs485, and rs422 standards while operating on a single 3v to 5.

While the rs485 specification does not specify cabling, these recommendations should be used for rs485 systems as well. Rs 422 can interoperate with interfaces designed to milstd188114b, but they are not identical. Though rs422 doesnt explicitly mention a maximum commonmode load, the standard specifies that a driver must be able to drive 10 receivers with a minimum input resistance of 4 k. Sixchannel rs422 line driverreceiver circuit cellar. Low power rs485rs422 transceiver stmicroelectronics. These unique devices employ a logically switched input resistance of 5k. Ltc2872 rs232rs485 dual multiprotocol transceiver with. Using the hs26ct31rh radiation hardened rs422 line. Differential impedance is the impedance the difference signal sees with no coupling, current into one line depends on capacitance per length of the line with coupling, current into one line depends on how the other line is driven the impedance of one line will depend on how the other line is driven. This represents the rs422 connections of a device, card or converter.

In a balanced differential system the voltage produced by the driver. How to properly configure and wire rs422 and rs485. Throughout this document the generic terms of rs 422 and rs 485 are used when referring to equipment and. They both use the same differential drive with identical voltage swings. Several dlsflsc h sensors connected to a rs485 line. Does your system use rs422, 2wire rs485, or 4wire rs485. Eiatia 422 defines a balanced differential interface. Some rs485 transceivers modify the input impedance to allow up to 8. An rs422 driver may have this signal, but it is not always required.

1093 311 1091 130 928 480 191 209 1013 950 334 1308 604 1132 66 327 987 746 65 1198 267 1560 1259 442 1270 1538 248 298 786 29 354 997 35 1070